Troubleshooting
mastRcam SC - TruVu Monitor Color Calibration
The following steps detail how to perform a basic color calibrations on TruVu monitors. It’s important to note that every customer site will not be exactly the same and definitely not with the same lighting, so the following steps are more of a basic ...
mastRcam SC - Battery/Inverter/Charging Issues
battery/inverter/charging issues (battery cables, water, loose screw, fuse, power cord, GFI, 120v breaker) If you are having issues with batteries not holding a charge, Inverter E01 or E05 errors, or batteries not charging....there are several things ...
mastRcam SC - Mast raises slowly and/or doesn't go up all the way
This is most likely an issue with water in the mast or freezing temperatures 1) If it had recently rained and if water is seen coming out of the weep holes when raising the mast, then draining the water out should fix the problem. To do this, raise ...
Invalid SDI Video or No Video Source (HD-100)
Typically if video is lost on the mastRcam camera system there are 2 types of errors you'll see on the monitor or UMR-20: NO VIDEO SOURCE AVAILABLE This error is typically a problem with the camera's signal and not the HD-100. You'll notice on the ...
mastRcam SC - Gray bars appearing in video (HD-100)
This is a normal function with the stabilizer (HD-100) trying to stabilize the video while the camera is moving. However, if you want to turn the stabilizer OFF, then here are instructions on turning it off (depending on what version controller you ...
mastRcam SC - Steps to factory default Kisea inverter.
Turn off inverter (If not already off) Turn on inverter When inverter is showing voltage press and hold the “power” and “select” button at the same time until “CU” is shown on the display. With “CU” on the display press the power button several times ...
mastRcam SC - Compressor Wont Turn On
1. Make sure the main power knob is ON as well as the inverter. The purple inverter controller, if it's on, should show a voltage reading. 2. Make sure the compressor switch on the dashboard is in the UP position 3. Make sure the mast control switch ...